130-200W Medical Open Frame
  • 130-200W Medical Open Frame130-200W Medical Open Frame

130-200W Medical Open Frame

Powereagle as the professional manufacturer, we would like to provide you high quality 130-200W Medical Open Frame. And we will offer you the best after-sale service and timely delivery.

Send Inquiry

Product Description

Powereagle as a professional high quality 130-200W Medical Open Frame manufacturer, you can rest assured to buy 130-200W Medical Open Frame from our factory and we will offer you the best after-sale service and timely delivery.

Features

• 4" x 2" Compact Size

• 2 x MOPP Compliance

• Protections : Short circuit / Over voltage / Over current / Over temperature

• Energy Efficiency ≥ 90%~93% depends on models

• No Load Power Consumption ≤ 0.3W

• MTBF > 100,000 hours

• Low Leakage Current

• 150W Convection / 200W Forced Air 

• Customized Solutions Available

EPM1153 U XX YY

U: Output range

XX: Specified output voltage, i.e. 12 is 12VDC

YY: Differential segmentation

General Specification

OUTPUT


Wattage Output VAC Universal Input Frequency Mechanical Size
130W Convection / 170W Forced Air 12VDC 100~240 50~60Hz 101.6L x 50.8W x 29H (mm)
15VDC
24VDC
48VDC
150W Convection / 200W Forced Air 12VDC
15VDC
24VDC
27VDC
48VDC

NOTE:

1 : Ripple & Noise is measured by using 20MHz bandwidth limited oscilloscope and terminated each output with a 0.1uF ceramic capacitor & parallel with 47uF aluminum capacitor at full load and nominal line.

2 : Line regulation is defined by changing ±10% of input voltage from nominal line at rated load.

3 : Max. Power (W) ≥ Vo x Io

INPUT

• Input Range 100 to 240 VAC

• Frequency 50 to 60Hz

• Input Current ≤ 3.15A

• Inrush Current ≤ 60A/230VAC

• Hold Up Time ≥ 8.3ms

• Turn On Time ≤ 1s

PROTECTION

• Short Circuit Protection Auto Recovery

• Over Current Protection Auto Recovery

• Over Voltage Protection Auto Recovery

• Over Temperature Protection Auto Recovery

ENVIRONMENT

• Operating Temperature -20 to 50°C

• Storage Temperature -40 to 85°C

• Operating Humidity 10% to 90 %

• Storage Humidity 5% to 95 %

DERATING CURVE

MECHANICAL

• Mechanical Size: 101.6L x 50.8W x 29H (mm)

• Pin Assignment:

AC Input Connector (CON1) : JST B3P-VH or equivalent

Pin No.

Assignment

Mating Housing

Terminal

1

AC/L

JSTVHRor equivalent

JST SVH-21T-P1.1 or equivalent

2

No Pin

3

AC/N

DC Output Connector (CON2) : JST B6P-VH or equivalent

Pin No.

Assignment

Mating Housing

Terminal

1,2,3

+V

JSTVHRor equivalent

JST SVH-21T-P1.1 or equivalent

4, 5,6

-V

• Weight: 200g

SAFETY

• Certified for whole series: CB IEC 60601-1, CE EMC(EN 60601-1-2),  CB IEC 62368-1, CE EMC(EN 55032+EN 55035), FCC Part 15B

• Complied with ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1,  TUV EN 60601-1, UL 62368-1, CAN/CSA C22.2 No. 62368-1,  TUV EN 62368-1

Hot Tags: 130-200W Medical Open Frame, China, Manufacturers, Suppliers, Factory, CE, Quality, Customized, In Stock, Bulk, Free Sample

Related Category

Send Inquiry

Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept